Protecting Wood Door Thresholds with Recessed Contacts

Edwards Signaling 12th Dec 2022
Protecting Wood Door Thresholds with Recessed Contacts

APPLICATION

For wood doors with aluminum thresholds, it is sometimes convenient to mount the magnet in the bottom of the door and the switch in the hollow space beneath the threshold.

Note: Because of the distance between the magnet and switch, a Sentrol wide gap switch should be used.

INSTALLATION

Select a recessed-mount wide gap Interlogix switch.

Drill horizontal hole for magnet in outside edge of door. Coat magnet with RTV mounting compound. Insert magnet in hole. If using a wide gap switch with bare magnet, insert with red end of magnet toward outside of door (switch is polarity sensitive).

Remove threshold.

Attach switch on inside of threshold with RTV mounting compound. Position it so it will be directly beneath (and parallel to) magnet when threshold is replaced.

Replace threshold.

Test switch with ohmmeter while opening and closing door.

Connect switch to alarm loop.

RECOMMENDED PRODUCTS

Protecting Wood Door Thresholds with Recessed Contacts
 
12th Dec 2022 Edwards Signaling

Recent Posts