SYMCOM 3-Phase Voltage Monitor

202-SYMCOM
Request for Quote
  • Manufacturer: Littelfuse
  • Product Family: SYMCOM
  • Product Type: Voltage Monitor
  • Frequency: 50/60Hz
  • Input Tolerance: +/-10%
  • Input Voltage: 190-480VAC
  • Max. Operating Temperature: 158 F
  • Min. Operating Temperature: -40 F
  • Mounting Method: 1/4 in Socket Head Cap Screw
  • Output Form: SPDT
  • Output Load Rating: 10A @ 240VAC
  • Output Load Rating Pilot Duty: 480VA @ 240VAC
  • Overvoltage Reset Voltage: 107%
  • Overvoltage Trip Voltage: 110%
  • Protection Rating: IP20
  • Restart Delay Range: Manual 2-300s adj
  • Trip Delay Range: Under/Over Voltage 4s; Unbalance/phasing faults - 2s
  • Trip Point Accuracy: +/-1%
  • Undervoltage Reset Voltage: 93%
  • Undervoltage Trip Voltage: 90%
  • Voltage Unbalance Reset: 4.5%
  • Voltage Unbalance Trip Point: 6%
SYMCOM 202 Series 3-Phase Voltage Monitor, auto-sensing voltage range, adjustable trip delay, 190-480 VAC 50/60Hz, SPDT, 5W, 480VA @ 240VAC pilot duty, 10A @ 240VAC gen purpose, 1/4 in socket head cap screw mount, LED visual indicator.
QTY

Contact Our Motion Control & Automation Experts

Contact our experts to answer questions or help you with your application needs.

Services

  • Control & Automation Engineering
  • Control Panel Services
  • Control System Design
  • Machine Vision Services
  • Maint/Repair Service Contracts
  • PLC Services
  • Rexroth Indramat Repair Center

Product Description

The 202 series is a 3-phase, auto-ranging, dual-range voltage monitor that protects 190-600VAC, 50/60Hz motors regardless of size. The 202-RP monitors the phase rotation of 3-phase systems and trips on reverse phase only. Critical applications include fan motors, scroll compressors, grinders, conveyor systems, elevators and escalators. Both products provide a user selectable nominal voltage setpoint and some models automatically select between the 200V and 400V range.

This unique microcontroller-based voltage and phase-sensing device constantly monitors the 3-phase voltages to detect harmful power line conditions. When a harmful condition is detected, the 202 series’s output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to acceptable levels.

The 202 series includes advanced single LED diagnostics. Five different light patterns distinguish between faults and normal conditions. The 202-RP monitors the phase rotation of 3-phase systems and trips on reverse phase only. Critical applications include fan motors, scroll compressors, grinders, conveyor systems, elevators and escalators. The status light turns green and the relay is activated when rotation is correct.